{{ variable.name }} : {{ variable.values[selectedVariantsIndex[variable_index]].name }}
cantidad:
| Number of inputs | 2, for 1 resistor bridge in full bridge technology |
| Alimentación | a través del E-bus |
| Relojes distribuidos | - |
| Measuring range UD | max. ±27 mV |
| Measuring range UREF | max. ±13.8 V |
| Internal resistance | > 200 kΩ (UREF), > 1 MΩ (UD) |
| Supported nominal sensitivity | all, parameter resolution: 0.01 µV/V; recommended: 0.5…4 mV/V |
| Input filter limit frequency | 10 kHz low pass (-3 dB) |
| Conversion rate | 100…4 samples/s (10…250 ms conversion time) |
| Power supply UV | up to 12 V DC from power contacts, dependent on sensor |
| Resolución | 16 bit, 32 bit presentation |
| Measurement error/ uncertainty | < ±0.01% for the calculated load value in relation to the final load value with a 12 V feed and 24 mV bridge voltage (hence nominal strain gauge characteristic value of 2 mV/V), self-calibration active, 50 Hz filter active |
| Consumo de corriente contactos de potencia | depends on strain gauge supply, min. 1 mA |
| Consumo de corriente E-bus | typ. 210 mA |
| Características especiales | self-calibration, quadruple averager, dynamic filters |
| Temperatura de funcionamiento/almacenamiento | 0…+55°C/-25…+85°C |
| Peso | approx. 60 g |
| Humedad relativa | 95%, sin condensación |
| Resistencia a vibraciones/choques | cumple la norma EN 60068-2-6/EN 60068-2-27 |
| Inmunidad/emisión CEM | cumple las normas EN 61000-6-2/EN 61000-6-4 |
| Proteger. clasificación/instalación pos. | IP20/variable |
| Homologaciones/marcas | CE, UL, ATEX, IECEx |
| Pluggable wiring | for all ESxxxx terminals |
| Marcado Ex | ATEX: II 3 G Ex ec IIC T4 Gc IECEx: Ex ec IIC T4 Gc |
descripción_de_sus_requisitos: